Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.
Packaging: 1 set/ carton
Packaging: 1 set/ carton
Packaging: 1 set/ carton
Packaging: Carton / wooden box Package dimensions on the product
Supply Ability: 300 Set/Sets per Month
Packaging: Carton / wooden box Package dimensions on the product
Supply Ability: 300 Set/Sets per Month mass flow meter
Packaging: Carton or wooden case
Supply Ability: 300 Set/Sets per Month We have mass flow meter in stock.
Packaging: Carton / wooden box Package dimensions on the product
Supply Ability: 300 Set/Sets per Month
Packaging: 1 set/ carton
Packaging: 1 set/ plywood case
Packaging: 1 set/ carton
Packaging: 1 set/ carton
Packaging: 1 set/ carton
Packaging: Carton / wooden box Package dimensions on the product
Supply Ability: 300 Set/Sets per Month
Packaging: 1 set/ carton
Packaging: 1 set/ carton
Packaging: 1 set/ carton
Packaging: 1 set/ carton
Packaging: 1 set/ carton
Sealand is a professional supplier of Chemical Mass Flow Meter, Chemical Mass Flowmeter, Chemical Flowmeter, Chemical Flow Meter, Chemical Coriolis Meter, ATEX, IECEx & CE approved.
The meter can work with a pulse receiver(Count). The connection is as follows. The resistance value is up to the cable length & the max. input pulse frequency of receiver. Current 10mA is suitable for most receivers; however, you can reduce the resistance value when the cable is long. The max. current could be 50mA. Please use the fixed frequency output function to check if the cable length & resistance value is suitable.
Please check following items before operation, and operate according to relevant rules. a) If the meter is damaged during shipment and installation;
b) If the voltage is same as marked on nameplate;
c) If the fuse is correct;
d) If the meter is grounded properly.
e) If the Meter SN on the nameplate of sensor and transmitter are the same.
If everything is fine, please open all valves, make the pipeline full of liquid and then power on the meter for warm-up for 20min before operation. Finally, conduct zero calibration after first start, and shall do it again if the meter is moved to another site.
Preparation for zero calibration:
a) Power on the meter for approximately 20min for warm-up;
b) Run the process fluid through the sensor until the sensor temperature reaches the normal process operating temperature.
c) Close the shutoff valve downstream from the sensor.
d) Ensure that the sensor is filled with fluid and the process flow has completely stopped.